Security and IT systems by type of building

An office, a warehouse and a residential tower need different things from the same systems. Here is what we usually propose for each, and a typical scope so you can see the scale. Your survey drawing is what decides it.

Offices and business centres

The priorities are a smooth front door, a server room only the right people can enter, attendance that feeds payroll, and Wi-Fi that works in every meeting room. Work has to happen around the business, often in the evenings.

  • Face terminal at the staff entrance for access and attendance
  • Readers on server, records and department doors
  • Cameras at entrances, reception and the server room only
  • Cat6 to desks, ceiling access points, guest Wi-Fi kept separate
  • Visitor check-in at reception
Business centre reception with an access reader at the glass entrance and a ceiling camera

Typical scope: 40-desk office

Illustrative, single floor, Business Bay

Face recognition terminal, staff entrance1
Door readers with controllers4 doors
Indoor dome cameras and recorder6
Cat6 data outlets52
Ceiling Wi-Fi access points4
Wall-mount rack with PoE switches and UPS1
Attendance software with payroll export1 site

Typical scope: logistics warehouse

Illustrative, 6,000 m², Dubai Investments Park

Outdoor bullet cameras, yard, gate and perimeter14
Indoor cameras, loading bays and racking aisles18
Recorder with 30 days of storage1
Face terminals for shift attendance2
Full height turnstile, staff gate1
Fibre link to gatehouse and office block2 runs
Wi-Fi access points for handheld scanners10

Warehouses, logistics and industrial

Long distances, high ceilings, dust, heat and shift workers. Cameras need longer lenses and infrared range, attendance has to handle a queue at shift change, and the network has to reach the gatehouse and the far end of the racking.

  • Bullet cameras with infrared for yards, gates and fences
  • Face terminals: quicker than fingerprints with gloves and dust
  • Full-height turnstiles or tripods at the staff gate
  • Fibre between buildings, Wi-Fi tuned around racking
  • Driver and contractor registration at the gate
Logistics warehouse with high racking and CCTV cameras mounted on the columns

Residential buildings and villa communities

Owners' associations and facility managers need common areas covered, residents let in without fuss, deliveries recorded, and CCTV that passes SIRA's audit. Villa owners want to see the gate on their phone.

  • Cameras in lobbies, lifts, car parks, pool and gym, planned to SIRA requirements
  • Access cards or face readers for lobby, car park barrier and amenities
  • Guest and delivery registration at the concierge
  • Guard room monitors and recorder with UPS
  • For villas: gate camera, video intercom and phone viewing
Residential tower lobby with a video intercom by the entrance and a dome camera

SIRA requirements for residential buildings

Typical scope: 20-floor residential tower

Illustrative, JLT

Cameras, lobby, lifts, car park, amenities, perimeter64
Recorders and guard room video wall1 set
Readers on lobby, car park and amenity doors12 doors
Car park barrier with reader2
Visitor and delivery management at concierge1
Annual maintenance with quarterly visits1

Typical scope: showroom with back office

Illustrative, Sheikh Zayed Road

Cameras at entrance, tills, displays, stockroom10
Readers on stockroom and cash office2 doors
Fingerprint terminal for staff attendance1
Cabling for POS, back office and cameras24 points
Customer and staff Wi-Fi, kept separate2 networks

Retail, showrooms and commercial properties

Clear faces at the door and the till, a locked stockroom and cash office, attendance across branches, and payment terminals on a network nobody else can reach. Landlords of commercial buildings add lobby access and car parks.

  • Identification-level cameras at entrances and tills
  • Readers on stockroom, cash office and staff entrance
  • Cloud attendance across several branches
  • Separate networks for POS, staff and customer Wi-Fi
  • For gold and jewellery shops: SIRA's stricter requirements planned in
Showroom with a ceiling dome camera and an access reader on the staff-only door

About these scopes. They are illustrative, to show the scale of a typical job. They are not past client projects. Real case studies will be added here with client permission.

Book a free site inspection

Tell us what the site is and what you need. An engineer will call to arrange a visit, walk the site with you and send a marked-up plan with an itemised quote.

+971 55 288 6114Call or WhatsApp, Monday to Saturday, 9:00 to 18:00
info@oneexpertis.comFloor plans and tender drawings welcome (PDF or DWG)
Al Wasl Building, Bur DubaiOffice 139, F5-B, Fifth Floor, near Bur Dubai Civil Defence
Please enter your name.
Please enter a number we can call, for example +971 50 123 4567.
Please choose the type of premises.

Sends your details to us on WhatsApp. We use them only to arrange your survey.