Cat6 vs Cat6A vs fibre: what to put in a Dubai office

Cat6 suits links that will stay at 1 Gbps, Cat6A is the safer choice for links that may need 10 Gbps or higher-power PoE, and fibre is for the backbone and anything beyond 100 metres. Here is how to decide for each part of a Dubai office.

Technician certifying a cable link with a handheld tester at a patch panel

The three options at a glance

Cat6 suits links that will stay at 1 Gbps, Cat6A suits links that may need 10 Gbps, and fibre is for the backbone and for anything beyond 100 metres. This Cat6 vs Cat6A Dubai office guide sets out the limits behind that summary, so you can decide what goes to each desk, camera and access point before you ask for a quote. The choice depends on the speed a link has to carry, how far it runs and whether it also powers a device over PoE.

We install all three as part of our structured cabling services in Dubai. The figures below come from the published cabling and Ethernet standards, not from any one manufacturer.

Cat6Cat6AFibre (OM3 multimode, OS2 single-mode)
Speed over 100 m1 Gbps10 Gbps1 or 10 Gbps, set by the switch modules
10 Gbps reachAbout 55 m100 m300 m on OM3; kilometres on OS2
Frequency rating250 MHz500 MHzNot rated this way: it carries light
Power over EthernetYesYes; the usual choice for higher-power PoE in large bundlesNo: glass carries no electrical power
Cable sizeThinner, fits tight trunkingThicker, needs more spaceThin and light, but must not be kinked
Typical useDesks, phones, printers, camerasHigh-capacity Wi-Fi, server rooms, long-life fit-outsLinks between floors, comms rooms and buildings

Both copper categories stop at 100 m per link, and that length includes the patch cords at each end. When a device is further from the rack than that, the answer is fibre, a rack closer to the device, or both.

Cat6: where it still fits

Cat6 is enough for any link that will stay at 1 Gbps, which in most offices means desks, phones, printers and cameras. It carries 1 Gbps over the full 100 m and 10 Gbps to about 55 m. It costs less than Cat6A, for the cable and for termination, and the thinner cable fits tight trunking.

Cat6 also carries Power over Ethernet. PoE+ (IEEE 802.3at) delivers up to 30 W at the switch port, and the access points we install run on PoE or PoE+. The limit to watch is higher-power PoE: IEEE 802.3bt delivers up to 60 W or 90 W at the switch port, and at those levels the cables in a large bundle warm up. Cat6A is the usual recommendation for those links.

Whichever category you choose, the jacks and patch panels should match it, because a link performs only as well as its lowest-rated part.

Cat6A: the safer default for a long-life fit-out

Cat6A is the copper category to choose when a link may need 10 Gbps while the cable is still in the ceiling. It is rated to 500 MHz, twice the Cat6 figure, and carries 10 Gbps over the full 100 m.

Cat6A is available unshielded and shielded. Ask which version a quote offers, and check that the jacks and patch panels are specified to match.

Four things point towards Cat6A:

  • Faster ports. Multi-gigabit ports (2.5 and 5 Gbps) are appearing on newer computers and access points, and Cat6A is the copper category rated for 10 Gbps over a full-length link.
  • High-capacity Wi-Fi and server rooms. A busy access point or a server carries the traffic of many users, so these links are the first to need more than 1 Gbps.
  • Higher-power PoE. Links that will carry 802.3bt power in a large bundle.
  • A fit-out meant to last. Replacing cable later means ceiling work and building management approval again.

The trade-off is cost and space. Cat6A costs more than Cat6, for the cable and for termination, and the thicker cable needs more room in trunking and tray, so size the containment for it from the start. The containment, the pulling and the testing are needed either way, so weigh the extra cost now against opening the ceilings again when the office next needs faster links.

Fibre: the backbone and anything beyond 100 m

Fibre carries light instead of an electrical signal, so it reaches far beyond the 100 m limit of copper. OM3 multimode carries 10 Gbps to 300 m, and OS2 single-mode reaches kilometres. It does three jobs:

  • Links between floors and comms rooms. We install OM3 and OM4 multimode fibre for these. The Cisco Catalyst switches we supply have SFP or SFP+ uplink ports that take fibre modules at 1 or 10 Gbps.
  • Devices more than 100 m from the rack. One copper link cannot reach them, so a second rack or a small switch goes closer to the devices and fibre joins it to the main rack.
  • Links between buildings. Glass fibre does not conduct electricity, which is why it is the safe way to link buildings. We use OS2 single-mode for longer runs and links to other buildings.

Fibre carries no electrical power, so it cannot deliver PoE. A camera or access point at the far end still plugs into copper, fed by a PoE switch in the local rack.

How the choice plays out in three typical offices

The survey decides the final design, but these three layouts are a fair starting point.

Small office on one floor

Cat6 to every desk, printer and camera is usually enough, with Cat6A to the access points if you want headroom. One wall-mount rack holds the patch panels, a PoE switch and the router. No fibre is needed as long as every outlet is within 100 m of cable from the rack.

Larger office on one floor

A mix works well: Cat6A to the access points, the server room and any desk that may need 10 Gbps, and Cat6 to the rest. One comms room holds a floor-standing rack with the patch panels, PoE switches and a UPS. Fibre is needed only if the cable route from the rack to the furthest outlet is longer than 100 m, measured along the route and not in a straight line.

Several floors or buildings

Each floor gets its own small rack (an IDF), with Cat6 or Cat6A running from it to the outlets on that floor. Fibre links each floor rack to the main comms room. This is the usual layout for a multi-floor tenant. We design the cabling, racks, switching and Wi-Fi together as one network and IT infrastructure job, so the fibre is matched to the switch ports at each end.

Testing and handover

An installed link is only proven to be Cat6 or Cat6A when it passes a certification test for that category. We certify every permanent link with a Fluke DSX-5000 against its category, and you receive a test result for every link, with its length. A link that fails should be re-terminated or re-pulled and tested again before handover, not after.

Fibre links are tested as well, and the results go into the same handover pack. The pack also holds the as-built drawing with outlet numbers, photos of the rack and containment, and a backup of the switch configuration. Every outlet and panel port carries a label that matches the drawing.

What to prepare before a cabling quote

A floor plan with desk positions is enough to start. These details make the first quote more accurate:

  • Floor plan with desks, meeting rooms, printers, cameras, door readers and Wi-Fi access points marked.
  • Ceiling type: false ceiling, exposed services or solid slab, because it changes the containment and the labour.
  • Comms room: where the rack will go and whether there is power there.
  • PoE devices, installed and planned: cameras, access points and door controllers.
  • Distances: a rough idea of the route from the rack to the furthest outlet, and any second building or gatehouse.
  • How long you expect to stay, and which desks or rooms may need more than 1 Gbps.

Then ask each bidder to state the category for each area (desks, access points, cameras, doors), unshielded or shielded, the fibre type for any backbone, and which tests and reports you will receive. We survey the containment and the comms room before quoting, and the quote lists outlets, cable, racks and network equipment separately. The pages on office Wi-Fi installation and CCTV installation cover the devices at the end of each link.

Questions

Is Cat6A worth the extra cost over Cat6 in a new Dubai office?

Usually yes for access points, server-room links and any fit-out that is meant to last. Cat6A costs more for the cable and the termination, but the containment, the pulling and the testing are needed either way, and replacing cable later means ceiling work again. For desks that will stay at 1 Gbps, Cat6 is enough.

Can I mix Cat6 and Cat6A on the same site?

Yes. A common split is Cat6A to access points and server-room links, and Cat6 to desks that will stay at 1 Gbps. Each link is certified against its own category, so the labels and the drawing should show which is which.

How long can a Cat6A cable be?

The limit is 100 metres per link, including the patch cords at both ends, and Cat6 has the same limit. The certification result for each link shows its measured length, so you can check the longest runs at handover.

Do CCTV cameras and access control readers need fibre?

Not usually. Cameras and door controllers connect over Cat6 or Cat6A, and many take their power from the same cable by PoE. Fibre comes in when a device is more than 100 metres of cable from the rack or in another building, and then it feeds a local switch, not the device itself.

Specify cabling for your Dubai site

Send a floor plan with desk positions and we will survey the site, then quote Cat6, Cat6A or fibre, racks and network equipment as separate items.

+971 55 288 6114Call or WhatsApp, Monday to Saturday, 9:00 to 18:00
info@oneexpertis.comFloor plans and tender drawings welcome (PDF or DWG)